Ion Chromatography

Category: Testing

Description: Ion Chromatography is an advanced, highly-accurate test process to identify contaminants on a PCBA which could lead to failure over time in the field, such a shorts between closely-spaced pads due to dendritic growth.

Process is optional and is turned OFF by default.

Major Cost Drivers -- PCBA Ion Chromatography

Ion Chromatography Cycle Time is either the sum of a total immersion in water, or a sum of testing specific locations.

If PSO Ion Chromatography Method = Full Immersion:

Full Immersion Process Time =  Board Load Time +
((Ion Chromatography Run Time) *
(MonitorPercentage/100))
Board Unload Time + Board Inspect Time

If PSO Ion Chromatography Method = Spot Test:

Spot Test Process Time =  Board Load Time +
((Ion Chromatography Run Time *
Ion Chromatography Spot Test Quantity)*
(Monitor Percentage/100))+ Board Unload Time +
Board Inspect Time

  • Board Load Time = (Machine variable)
    • Board Unload Time = (Machine variable)
    • Board Inspect Time = (Machine variable)
    • Ion Chromatography Run Time = (Machine variable)
      • Ion Chromatography Spot Test Quantity = (Machine variable)
    • Monitor Percentage = (Machine variable)

User Inputs –- PCBA Ion Chromatography

PSO: Ion Chromatography Method (Full Immersion or Spot Test)